CHAPTER 2 Connected Information 2.3 Power cable connection

100 V Redundant Power Feed Configuration (Single power feed, Redundant Power Feed)

It is necessary to arrange four PSUs, two FANUs and four power supply cables (100 V NEMA 5-15P) for 100V redundant power feed configuration (single power feed, redundant power feed).

FIGURE 2.14 100V Redundant Power Feed Configuration (Single power feed, Redundant Power Feed)

Number

Description

(1)Distribution Panel AC100V AC#0system

Standard Configuration of 200 V (single power feed, no redundant power feed) with Power Distribution Box Connection

It is necessary to arrange two PSUs, four FANUs, two power cables (200 V IEC60320 C20) and two power distribution boxes (200 V IEC60320 C19×3type) for standard configuration of 200 V (single power feed, no redundant power supply).

When the power distribution box is used, it is necessary to secure the breaker characteristic of distribution panel. See 2.6 Cutoff Characteristics of Distribution Panel (At the time of connecting power distribution box).”

FIGURE 2.15 Standard Configuration of 200 V (single power feed, no redundant power feed) with Power

Distribution Box Connection

Number

Description

(1)

Power distribution box (200V C 19 3 type)

 

 

 

23