CHAPTER 2 Connected Information 2.3 Power cable connection
200 V Redundant Power Feed Configuration (with single power feed, redundant power feed) with Power Distribution Box Connection
It is necessary to arrange three PSUs, three FANUs, three Power cables (200 V IEC60320 C20) and two power distribution box (200 V IEC60320 C19×3type) for of 200 V Redundant Power Feed Configuration (single power feed, redundant power feed).
When the power distribution box is used, it is necessary to secure the breaker characteristic of distribution panel. See “2.6 Cutoff Characteristics of Distribution Panel (At the time of connecting power distribution box).”
FIGURE 2.16 200 V Redundant Power Feed Configuration (single power feed, redundant power feed) with
Power Distribution Box Connection
Number | Description |
(1) | Power distribution box (200V C 19 3 type) |
200V Dual Power Feed Configuration with Power Distribution Box Connection
It is necessary to arrange four PSUs, two FANUs, four power cables (200 V IEC60320 C20) and two power distribution box (200 V IEC60320 C19×3type) for 200 V dual power feed configuration for Japan and Overseas.
When the power distribution box is used, it is necessary to secure the breaker characteristic of distribution panel. See “2.6 Cutoff Characteristics of Distribution Panel (At the time of connecting power distribution box).”
FIGURE 2.17 200 V Dual Power Feed Configuration with Power Distribution Box Connection
Number | Description |
(1) | Power distribution box (200V C 19 3 type) |
|
|
|
24 |