Fujitsu MB91401 Evaluation MCU terminal name, Pin treatment, Signal line name, Wiring regulations

Models: MB91401

1 72
Download 72 pages 18.2 Kb
Page 22
Image 22
Evaluation MCU terminal name

MB91401

Prelminary

2004.11.12

 

 

Precaution when designing

When evaluation MCU on the user system is operated in the state that the emulator is not connected, should be treated as follow each input terminal of evaluation MCU connected with the emulator interface on the user system.

Therefore, note that the switch circuit etc, might become necessary in the user system when you design.

The terminal processing in each emulator interface is shown as follows.

Pin treatment of emulator interface (DSU-3)

Evaluation MCU terminal name

 

Pin treatment

 

 

 

 

 

RST

 

 

To be connected the RST terminal with the reset output circuit in the

 

 

user system.

 

 

 

 

 

 

 

 

Others

 

 

To open.

 

 

 

 

 

Emulator interface wiring regulations

 

 

 

Signal line name

 

 

Wiring regulations

 

 

 

 

ICLK

The total wiring length of each signal (From evaluation MCU pin to the

 

ICS2 to ICS0

 

emulator interface connector pin) is made within 50 mm.

 

ICD3 to ICD0

The difference of the total wiring length of each signal makes within 2 cm

 

BREAKI

 

and the total wiring length of ICLK is the shortest.

 

 

 

 

 

Wire the pattern with capacity more than the ratings current.

 

UVCC

Each power supply and GND may cause a short-circuit or reverse connec-

 

 

tion in between by a wrong connection of a probe. Insert a protection circuit

 

 

 

 

 

 

such as a fuse into each power supply pattern to safeguard it.

 

 

 

 

GND

Connect directly with a power supply system pattern such as grandopran.

 

 

 

 

 

 

Reference document

Please match and refer to the following manual for the connection with ICE.

DSU-FR Emulator MB2198-01 Hardware Manual

FR20/30 series MB2197-01 Hardware Manual

22

Page 22
Image 22