2. Recommended Operating Conditions

MB91401

Prelminary

2004.11.12

 

 

2. Recommended Operating Conditions

(VSS = PLLVSS = 0 V)

Parameter

Symbol

 

Value

 

Unit

 

 

 

Min

Typ

Max

 

 

 

 

 

 

 

 

 

 

 

Power supply voltage

I/O

VDDE

3.0

3.3

3.6

V

 

 

 

 

 

 

Internal

VDDI

1.65

1.8

1.95

V

 

 

 

 

 

 

 

 

Analog power supply voltage

PLLVDD

VSS + 3.0

VDDE

V

 

 

 

 

 

 

Operating temperature

Ta

10

70.0

°C

 

 

 

 

 

 

 

WARNING: The recommended operating conditions are required in order to ensure the normal operation of the semiconductor device. All of the device’s electrical characteristics are warranted when the device is operated within these ranges.

Always use semiconductor devices within their recommended operating condition ranges. Operation outside these ranges may adversely affect reliability and could result in device failure.

No warranty is made with respect to uses, operating conditions, or combinations not represented on the data sheet. Users considering application outside the listed conditions are advised to contact their FUJITSU representatives beforehand.