Interface

At command issuance (I/O registers setting contents)

 

1F7H(CM)

1

 

1

 

0

 

0

 

0

1

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1F6H(DH)

x

L

x

DV

Start head No. / LBA

 

 

 

 

 

 

 

 

 

 

 

 

 

[MSB]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1F5H(CH)

Start cylinder No. [MSB] / LBA

 

 

 

 

 

1F4H(CL)

Start cylinder No. [LSB] / LBA

 

 

 

 

 

1F3H(SN)

Start sector No. / LBA [LSB]

 

 

 

 

 

1F2H(SC)

Transfer sector count

 

 

 

 

 

 

1F1H(FR)

xx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

At command completion (I/O registers contents to be read)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1F7H(ST)

 

Status information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1F6H(DH)

 

x

 

L

 

x

 

DV

 

End head No. / LBA [MSB]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1F5H(CH)

 

End cylinder No. [MSB] / LBA

 

 

 

 

 

1F4H(CL)

 

End cylinder No. [LSB] / LBA

 

 

 

 

 

1F3H(SN)

 

End sector No. / LBA [LSB]

 

 

 

 

 

1F2H(SC)

 

00(*1)

 

 

 

 

 

 

 

 

 

 

 

 

1F1H(ER)

 

Error information

 

 

 

 

 

 

 

*1 If the command is terminated due to an error, the remaining number of sectors for which data was not transferred is set in this register.