5.3 Host Commands

(33) SECURITY FREEZE LOCK (X’F5’)

This command puts the device into FROZEN MODE. The following commands used to change the lock function return the Aborted Command error if the device is in FROZEN MODE.

SECURITY SET PASSWORD

SECURITY UNLOCK

SECURITY ERASE PREPARE

SECURITY ERASE UNIT

SECURITY DISABLE PASSWORD

FROZEN MODE is canceled when the power is turned off, or when hardware is resented. If this command is reissued in FROZEN MODE, the command is completed and FROZEN MODE remains unchanged.

Issuing this command during LOCKED MODE returns the Aborted Command error.

The following medium access commands return the Aborted Command error when the device is in LOCKED MODE:

READ SECTORS (EXT)

WRITE SECTORS (EXT)

WRITE VERIFY

READ VERIFY SECTORS (EXT)

READ MULTIPLE (EXT)

WRITE MULTIPLE (EXT/FUA EXT)

READ DMA (EXT)

WRITE DMA (EXT/FUA EXT)

DEVICE CONFIGURAION RESTORE

DEVICE CONFIGURAION SET

SECURITY SET PASSWORD

SECURITY FREEZE LOCK

SECURITY DISABLE PASSWORD

FLUSH CACHE (EXT)

SET MAX ADDRESS (EXT)

C141-E218

5-99

Page 175
Image 175
Fujitsu MHV2100AT, MHV2080AT, MHV2120AT, MHV2040AT, MHV2060AT manual Security Freeze Lock X’F5’