5.3 Host Commands

Bits 12-8:

In the case of Device 1 (slave drive), a valid value is set.

 

Bit 12:

Reserved

 

Bit 11:

'1' = Device asserts PDIAG-.

 

Bit 10, 9:

Method for deciding the device No. of Device 1.

 

 

'00' = Reserved

 

 

'01' = Using a jumper.

 

 

'10' = Using the CSEL signal.

 

 

'11' = Other method.

 

Bit 8:

= '1' (In the case of device 1)

Bits 7-0:

In the case of Device 0 (master drive), a valid value is set.

 

Bit 7:

Reserved

 

Bit 6:

'1' = Device 1 is selected, Device 0 responds.

 

Bit 5:

'1' = Device 0, assertion of DASP- was detected.

 

Bit 4:

'1' = Device 0, assertion of PDIAG- was detected.

 

Bit 3:

'1' = Device 0, an error was not detected in the self-

 

 

diagnosis.

 

Bit 2, 1:

Method for deciding the device No. of Device 0.

 

 

'00' = Reserved

 

 

'01' = Using a jumper.

 

 

'10' = Using the CSEL signal.

 

 

'11' = Other method.

 

Bit 0:

'1'= (In the case of device 0)

*21 WORD 94

Bit 15-8: X'FE' Recommended acoustic management value.

Bit 7-0: X'XX' Current set value.

FE-C0: Performance mode

BF-80: Acoustic mode

00:Acoustic management is unused it. (It is same as "FE-CO")

*22 WORD 100-103

When "48 bit LBA" of the option (customize) is supported, same number of LBA as WORD 60-61 is displayed.