Table 5.34 Features field values and settable modes (2/2)

Features

 

Drive operation mode

 

Field

 

 

 

 

 

 

 

 

 

 

 

 

X '88'

 

Undefined

(Note 1)

 

 

 

 

 

X '8B'

 

Disable Write-Read-Verify feature set.

*5

 

 

 

 

X '90'

 

Disables the Serial ATA function.

 

 

 

 

 

 

X '99'

 

Undefined

(Note 1)

 

 

 

 

 

X 'AA'

 

Enables the read cache function.

 

 

 

 

 

X 'BB'

 

Specifies the transfer of 4-byte ECC for READ LONG and WRITE LONG

 

 

commands. (Note 1)

 

 

 

 

 

 

 

 

X 'C2'

 

Disables the Acoustic management function.

 

 

 

 

X 'CC'

 

Enables the reverting to power-on default settings after software reset. (Note 1)

 

 

 

 

X 'DF'

 

Clearing DRQ bit to zero when error bit is set is disabled.

 

 

The drive executes the dummy transferring. (Note 2)

 

 

 

 

Note 1:

Although there is a response to the command, nothing is done.

 

Note 2: Although there is a response to the command and this command reflects on Identify Device information, DRQ bit is always cleared to zero when error is occurred in PIO read command (This drive always doesn't the dummy transferring).

At power-on, the default mode is set as follows:

 

Write cache function:

Enabled

Transfer mode:

PIO Mode-4, Multiworld

 

DMA Mode-2

Advanced power management function:

Enabled (Mode-1)

Acoustic management function:

State keeping

Read cache function:

Enabled

At power-on or COMRESET, the default mode of Serial ATA function is set as follows:

DMA Setup FIS Auto-Activate optimization: Disabled

Device-initiated interface power state Transitions: Disabled

Software Settings Preservation:

Enabled

5-120

C141-E269