Theory of Device Operation

4.4 Power-on Sequence

Figure 4.3 describes the operation sequence of the disk drive at power-on. The outline is described below.

a)After the power is turned on, the disk drive initializes its SATA interface block.

b)The disk drive executes the MPU bus test, internal register read/write test, and work RAM read/write test. When the self-diagnosis terminates successfully, the disk drive starts the spindle motor.

c)The disk drive executes self-diagnosis (data buffer read/write test).

d)After confirming that the spindle motor has reached rated speed, the head assembly is loaded on the disk.

e)The disk drive positions the heads onto the SA area and reads out the system information.

f)The drive becomes ready. The host can issue commands.

g)The disk drive executes self -calibration. This collects data for VCM torque and mechanical external forces applied to the actuator, and updates the calibrating value.

4-6

C141-E269

Page 64