PRIMERGY TX200 S2 User’s Guide
6
High Reliability Tool

When an error screen appears after installation (Windows Server

2003 only)

If Windows Server 2003 Service Pack 1 is applied, when restarting after installing/uninstalling RAID
Management Tool (Global Array Manager) the following message may appear.
There is no problem with operations. Click [Close Message] to close the message.
6.1.2 Settings when using RAID Management Tool in Linux
When using RAID Management Tool in a Linux environment, after installing Global Array Manager,
use the following procedures to change the GAM Server service activation sequence. When Linux is a
bundle type perform settings changes.
Log in with "root".
This setting is necessary when the GAM version is "6.02-18". If the GAM version is unknown, check as
shown below using the rpm command.
1Edit "/etc/init.d/gam" in the text editor.
Using the vi command etc., change the chkconfig setting at located at the start of the file.
2Reflect the changed settings.
Execute the following commands and after temporarily deleting the GAM Server service re-
attach it.
3Check if the changed settings are reflected correctly.
Execute the following commands and check if the service is "on" in run level 2 to 5.
In order to protect the computer, this program is terminated by
Windows.
Name: SNMP Service
# rpm -q gam-server
gam-server-6.02-18
# vi /etc/init.d/gam
# chkconfig: 2345 40 60
Change
# chkconfig: 2345 99 60
# chkconfig --del gam
# chkconfig --add gam
# chkconfig --list gam
gam 0:off 1:off 2:on 3:on 4:on 5:on 6:off