273
PRIMERGY TX200 S2 User’s Guide
9
Operation and Maintenance
Server Management Tools Error Messages

The following error messages may appear while executing Server Management Tools. In such cases,

perform the corresponding resolutions. If messages other than the following are displayed, refer to

"Contact Information" in "Start Guide", and contact your maintenance engineer.

table: List of Server Management Tools Error Messages
Message Description
Write protect error writing drive A.
Abort, Retry, Fail?
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
Not ready writing drive A.
Abort, Retry, Fail?
The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk ("Server
Management Tools" disk), and then press the [R] key.
ERROR:Fail to create data file. The following are possible causes. Check the floppy
disk status again.
• The floppy disk is write-protected. Disable the
write-protect and retry.
• The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk, and then retry.
• The floppy disk contains abnormal contents. Create
"Server Management Tools" again. If this occurred
while recovering BIOS information, configure the
information using the BIOS Setup Utility. Then store
the BIOS information.
ERROR:Fail to write 1st CMOS data into data file. nn
ERROR:Fail to write 2nd CMOS data into data file. nn
ERROR:Fail to write ESCD data into the data file. nn
ERROR:Fail to write SEEPROM data into the data file.
nn
ERROR:Fail to open data file. The file for recovering the BIOS information does not
exist on this floppy disk. Insert the floppy disk on
which the BIOS information was stored, and then retry.
ERROR:Fail to write 1st CMOS data into system. nn The following are possible causes. Check the floppy
disk status again.
• The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk, and then retry.
• A different model or an unsupported version of
BIOS information. Insert the proper floppy disk, and
then retry.
• The floppy disk contains abnormal contents. Create
"Server Management Tools" again. If this occurred
while recovering BIOS information, configure the
information using the BIOS Setup Utility. Then store
the BIOS information.
ERROR:Fail to write 2nd CMOS data into system file.
nn
ERROR:Fail to write ESCD data into system file. nn
ERROR:Fail to write SEEPROM data into system. nn
Other messages Refer to "Contact Information" in "Start Guide", and
contact your maintenance engineer.