257
PRIMERGY TX200 S2 User’s Guide
8
Configuring Hardware and utilities
Device Properties Submenu

Select [Device Properties] in the [Adapter Properties] window and press the [Enter] key to display the

submenu.

RAID Properties Submenu

Select [RAID Properties] in the [Adapter Properties] window and press the [Enter] key to display the

submenu.

table: Items on the Device Properties Submenu
Item Setting Description
Restore Defaults Reads default values for the controller.
MT/Sec • 80 (at the time of
purchase)
•40
•20
•10
•5
•0
Sets the maximum transfer rate.
MB/Sec Displays the maximum transfer rate.
Data Width • 16 (at the tim e of
purchase)
•8
Specifies the maximum data transfer width.
Scan ID Yes (at the time of
purchase)
•No
Sets whether or not to scan this device at startup.
Scan LUNs > 0 • Yes (at the time of
purchase)
•No
Sets whether or not to scan LUN=1 and subsequent
LUNs at startup.
DISCONNECT • On (at the time of
purchase)
•Off
Sets whether or not to permit disconnection during
command execution.
SCSI Timeout 10 Specifies the timeout period during command
execution.
QUEUE TAGS • On (at the time of
purchase)
•Off
Sets whether or not to issue multiple commands to
devices at the same time.
table: Items on the RAID Properties Submenu
Item Setting Description
Array Disk? No (Fixed parameter) Sets whether or not to configure an array.
The server does not support this yet. Cannot be set.
Hot Spare No (Fixed parameter) Sets whether or not to configure a hot spare.
The server does not support this yet. Cannot be set.