4. NAVTEX OPERATION: NAVNET

MAX ERROR RATE

33%

Max error rate entry window

14.Rotate the [ENTER] knob to enter maximum allowable error rate to use. The setting range is 0-33%. Any message with an error rate higher than that entered here will be rejected.

15.Press the ENTER soft key.

16.Rotate the [ENTER] knob to choose ALARM (SAR MSG) and press the EDIT soft key.

ALARM (SAR MSG)

§°ON

OFF

Alarm (SAR MSG) options

17.Rotate the [ENTER] knob to choose ON to get the audio alarm when an SAR (Search and Rescue) message is received, or OFF for no audio alarm when an SAR message is received.

Note: Message category D must be selected to get the audio alarm.

18.Press the ENTER soft key.

19.Rotate the [ENTER] knob to choose ALARM (WARNING MSG) and press the EDIT soft key.

ALARM (WARNING MSG)

§°ON

OFF

Alarm (warning msg) options

20.Rotate the [ENTER] knob to choose ON to get the audio alarm when an A, B, or L category message is received, or choose OFF for no audio alarm.

Note: Message category A, B or L must be selected to get the audio alarm.

21.Press the [RETURN] soft key.

Note: When the above alarms are enabled, the audio alarm sounds and the speaker icon () appears when an SAR message or category A, B, D or L message is received. Press the [CLEAR] key to silence the audio alarm. You can see which type of message you have received by pressing the [ALARM] key to display the alarm message board.