2.3 Processor Unit

Cables (10S2074, 10S1258-1 and control cable) from the various units are connected to the CONE Board (10P6905) in the processor unit.

NOTICE

Divide cables attached to the back of the processor unit between right and left side. Tie each group with a cable tie at the position 15 cm from connectors.

This is necessary to prevent cable stress.

15 cm

Cable tie

Processor unit, rear view

2.3.1 10S1258-1 cable

This cable runs between the processor unit and transceiver unit.

Shield

Anticorrosive Sheath

 

19

8

9

10

18

7

2

3

11

17

6

1

4

12

 

 

5

 

 

16

13

15 14

 

1. BLK

 

9. BLK/GRY

17. BRN/GRY

 

2. BLK/BRN

10. BLK/WHT

18. BRN/WHT

 

3. BLK/RED

11. BRN/RED

19. RED/ORG

 

4. BLK/ORG

12. BRN/ORG

 

 

5. BLK/YEL

13. BRN/YEL

 

 

6. BLK/GRN

14. BRN/GRN

 

 

7. BLK/BLU

15. BRN/BLU

 

 

8. BLK/PPL

16. BRN/PPL

 

Armor

1:

Coaxial cable

 

 

 

2 to 19: Twisted pair cable

Cable type 10S1258-1, sectional view

2-4

Page 26
Image 26
Furuno FSV-30S installation manual 1 10S1258-1 cable, Cable type 10S1258-1, sectional view