Passing the cable through the bottom of the control unit (for permanent mounting) For permanent mounting methods (2) and (3), the control cable can be passed through the bottom of the control unit as follows:

1.Unfasten eight screws (M4) to remove the cover from the bottom of the control unit.

2.Unscrew two screws (M410) to remove the cable clamp.

3.Disconnect two connectors J1 and J2 from the circuit board.

4.Attach the control cable to the control unit cover with the cable clamp (removed at step 2), two flat head screws (M4), flat washers, spring washers and nuts (hardware: supplied).

Screw

M4x8 (8 pcs.)

Clamp

Nut

Previous cable hole

Spring washer

Flat washer

Screw (M4x12)

Fasten the cable with the clamp here.

Control unit, cover removed

5.Re-connect two connectors disconnected at step 3.

6.Fasten eight screws to attach the control unit cover.

7.Attach the connector seal (supplied) to the hole at the rear of the control unit.

8.Drill a hole of 30 mm in diameter to pass the cable from the bottom of the control unit through the tabletop

9.Attach the connector seal (supplied) to the hole at the bottom of the control unit when the above modification is not done.

10.Fix the control unit referring to (2) or (3) on the previous page.

Cable

Cable

 

Without KB fixing plate

With KB fixing plate

Control unit, side view

1-11