1.1.5 Installing stays (anti-vibration measure)

Install stays from the top of the hull unit to the ship’s hull. The stays should be angle iron with a size of 75759 mm or more and at least two pieces should be used; one each to ship’s bow and stern directions. Install if possible, two more stays in ship’s transverse direction. This measure must be done to prevent damage to the transducer.

Bow

Stay

Stay

Hull Unit

Proper installation of stays

Do not install the stays on a crossbeam on an overhead. Vibration-resistance effect is reduced since vibration is applied to the stays as rotation force. Install them horizontally.

 

Crossbeam

 

on overhead

Stay

(WRONG installation method)

Eye Bolt

 

PROPER installation

Hull Unit

90

 

Proper and improper stay installation methods