1.1.2 Shortening the retraction tank

The retraction tank is 1300 mm in length when supplied. Shorten the tank as necessary so that the transducer positions well below the keel when it is fully lowered. The following table provides guidelines for shortening the tank. Refer also to the retraction tank installation drawing at the back of this manual.

Installation

 

 

 

 

 

 

 

 

Method

 

 

 

D

 

 

 

D

 

 

 

 

 

 

XDCR Travel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove 280

 

Remove 280 - 290 mm

 

 

 

 

 

- 290 mm

 

from the bottom.

 

 

 

 

1200 mm

from the

Same as left.

Note that the length

Same as left.

bottom.

stroke

 

"D" must be less than

 

 

 

 

 

 

1170 mm.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove

 

Remove less than

 

 

 

 

 

 

290 mm from the

 

 

 

 

 

less than

 

Same as left.

 

 

bottom. Note that the

1600 mm

290 mm

Same as left.

length "D" must be less

 

 

 

 

from the

 

 

 

 

stroke

 

than 1570 mm.

 

 

 

 

 

bottom.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Guidelines for shortening the retraction tank

Note 1: For the 1200 mm stroke hull unit, the transducer will not fully protrude unless the tank is shortened by at least 280 mm from the bottom, and cannot be fully retracted if more than 290 mm is removed.

Note 2: For the 1600 mm stroke hull unit, the transducer cannot be fully retracted if the tank is removed more than 290 mm.

Note 3: When 290 mm is removed and “D” is minimum, the effect of air foam is minimized because the transducer fully protrudes in water.