How to check the hull unit

1.Press the POWER () switch on the control unit to turn on the equipment. Confirm that “ ON” lamp above the POWER switch and theª switch light.

 

 

 

Transducer switches of the control unit

2.

Confirm that the 5V and UP lamps on the raise/lower control box are lit.

3.

Remove the cover of the raise/lower control box and use a multimeter to measure the

 

following voltages:

 

 

 

 

 

 

 

 

 

 

Terminal

Terminal No.

Voltage

 

 

 

TB-C101

(1) – (2), (6) – (7)

220 VAC

 

 

 

 

(2) – (3), (7) – (8)

220 VAC

 

 

 

 

(1) – (3), (6) – (8)

220 VAC

 

4.

In the raise/lower control box, set the TEST/NORMAL switch to TEST. Press the

 

[DOWN] switch to confirm that the transducer lowers. Also, while the transducer is being

 

lowered, check that the MD LED lights when the MD L. SW kicks. Note that the MD L.

 

SW does not stop the transducer when the TEST/NORMAL switch is in the TEST

 

position.

 

 

 

TEST

 

OFF

 

5V

NORMAL

 

L.SW

 

UP

MD

DN

UP

DOWN

Control unit (in hull unit)

5.Press and release the [DOWN] switch. Confirm that the transducer stops at the moment the switch is released.

6.Press the [DOWN] switch again. Confirm that the transducer stops at the moment the lower limit switch kicks.

7.Confirm that the [UP] switch operates in a similar manner.

3-3