2.6 Input Voltage and Fuses

The transceiver unit is shipped from the factory with its input voltage set for 230 VAC and a 10 A fuse inserted in F601 and F602. For other voltages, change toggle switch positions and fuses as below.

Input voltage

Set the toggle switches S603, S604 and S605 according to input voltage, referring to the table below.

Input

S603

S604

S605

Default setting

(TB-B101)

 

 

 

 

100 V

L

L

L

 

110 V

H

L

L

 

115 V

H

H

L

 

220 V

H

L

H

 

230 V

H

H

H

Default setting

Fuses

Change the fuse in F601 and F602 according to input voltage, referring to the table below.

Input

 

Fuse

Default

(TB-B101)

F601

F602

setting

100 V

 

 

 

110 V

20A

20A

 

115 V

 

 

 

220 V

10A

10A

Default

230 V

setting

 

 

WARNING

Use the proper fuse.

Use of a wrong fuse can result in damage to the equipment or cause fire.

Marking the label

After setting toggle switches and changing the fuses, mark the voltage which applies on the label on the inside of the cover. In the example shown right, 100 V is marked so 20A fuses must be used.

FUSE

FUSE

F601

F602

INPUT

FUSE

(TB-B101)

F601

F602

100V

 

 

110V

20A

20A

115V

 

 

220V

10A

10A

230V

 

 