2.4.2 Fabrication of power cable type DPYCYS-2.5 (TB-B101)

Fabricate the cable DPYCYS-2.5 as below for connection to the power source.

Cable DPYCYS-2.5

Armor

Vinyl sheath

Conductor

S= 4 mm2 = 2.55 mm

140

35

30

FV2-4 (2 pcs)

Anticorrosive

Amor

Vinyl sheath

sheath

 

 

Fabrication of cable type DPYCYS-2.5

2.4.3 Hull control cable (10S2078)

Connect the hull control cable (10S2078) to the CN-B102 in the transceiver unit.

Note: The same type of connector is fitted at each end, however the connector which has a larger portion of its sheath removed should be connected to the transceiver unit.

2-12

Page 34
Image 34
Furuno FSV-30S installation manual Fabrication of power cable type DPYCYS-2.5 TB-B101, Hull control cable 10S2078