13. MAINTENANCE & TROUBLESHOOTING

13.1 Maintenance

Regular maintenance is essential for good performance. A maintenance program should be established and should at least include the items listed in Table 13-1.

WARNING

Do not open the equipment.

Hazardous voltage which can cause electrical shock, burn or serious injury exists inside the equipment. Only qualified personnel should work inside the equipment.

Table 13-1 Recommended maintenance program

Item

Check point

Remedy

 

 

 

Antenna

Check for loosened and corroded

Tighten loosened bolts. Replace heavily corroded

bolts.

bolts.

 

 

 

 

 

Check connection point for

 

 

watertightness.

 

 

 

 

Antenna cable

Check connector for tightness and

Replace damaged parts.

 

corrosion.

 

 

 

 

 

Check cables for damage.

 

 

 

 

Display unit

Check for tight connection.

Tighten loosened connectors.

connectors

 

 

 

 

 

Ground terminal

Check for tight connection and

Clean or replace as necessary.

corrosion.

 

 

 

 

 

 

 

Dust may be removed with a soft cloth. if

Display unit

Dust and foreign material on the

necessary anti-static cleaner may be used. Never

display unit.

use chemical solvents to clean the display; they

 

 

 

can remove paint and markings.

 

 

 

 

 

Wipe the LCD carefully to prevent scratching,

 

 

using tissue paper and an LCD cleaner. To

 

 

remove dirt or salt deposits, use an LCD cleaner,

LCD

Dust and foreign material on the

wiping slowly with tissue paper so as to dissolve

screen.

the dirt or salt. Change paper frequently so the

 

 

 

salt or dirt will not scratch the LCD. Do not use

 

 

solvents such as thinner, acetone or benzene for

 

 

cleaning.

 

 

 

 

Check the transducer face yearly

Gently scrape off any marine life from the

Transducer

for marine life, which can reduce

transducer with a piece of wood.

 

sensitivity.

 

 

 

 

 