Furuno GP-1650F, GP-1650DF manual Changing Track Memory Capacity, Track plotting interval

Models: GP-1650DF GP-1650F

1 109
Download 109 pages 50.07 Kb
Page 37
Image 37

PLOT

'TIME

DISTANCE

Figure 4-5 Plot window

4.Press or to select TIME or DIS- TANCE. Distance is useful for conserv- ing track memory, since no track is recorded when the boat is stationary.

5.Press the soft key ENTER or the [ENTER] key.

Track plotting interval

1.Press the [MENU] key followed by the soft keys CHART SETUP OPTIONS and

TRACK CONTROL.

2.Press or to select TIME INTERVAL or DIST INTERVAL.

3.Press the soft key EDIT to display the in- terval window.

TIME INTERVAL

01 m 00 s

(When selecting TIME INTERVAL.)

DIST INTERVAL

00.10 nm

(When selecting DIST INTERVAL.)

Figure 4-6 Interval window

4.Use the cursor pad to place the cursor on the digit desired. The [CLEAR] key func- tions to clear an entire line of data.

5.Press appropriate alphanumeric key to enter value.

6.Repeat steps 4 and 5 to complete.

7.Press the soft key ENTER or the [ENTER] key.

4.5Changing Track Memory Capacity

The equipment stores a total of 5000 points of track and marks. This total may be freely apportioned as desired. The default setting is 2000 points of track and 3000 marks. You can change the memory capacity for track and marks. Note that when this is done all tracks and marks in the memory are erased.

1.Press the [MENU] key followed by the soft keys CHART SETUP OPTIONS and

TRACK CONTROL.

2.Press to select TRACK MEMORY.

3.Press the soft key EDIT to display the TRACK MEMORY window.

TRACK MEMORY

1000/5000 POINTS

Figure 4-7 TRACK MEMORY window

The TRACK MEMORY window may be erased by pressing the soft key CANCEL to escape.

4.Enter number of track memory points desired with the alphanumeric keys.

Note that all digits may be cleared by pressing the soft key CLEAR or the [CLEAR] key in entering track memory points.

5.Press the soft key ENTER or the [ENTER] key. The following window appears to ask you if you are sure to change the track memory capacity.

RESETTING ERASES

TRACK, MARK/LINE

ALREADY SAVED. OK?

YES ... "ENTER" key

NO ... "CLEAR" key

Figure 4-8 ERASE messege

6.Press the [ENTER] key to change appor- tion, or press the [CLEAR] key to escape.

4-3

Page 37
Image 37
Furuno GP-1650F, GP-1650DF manual Changing Track Memory Capacity, Track plotting interval