3.6 Troubleshooting

The table below provides basic troubleshooting procedures which the user may follow to restore normal operation.

Troubleshooting table

If…

 

Then check …

neither echo nor

battery voltage.

fixed range scale

fuse.

appears

power supply.

 

 

power cable.

no echo appears

if display advance

but the fixed

 

speed is set to “Stop.”

range scale

transducer plug

appears

 

 

echo appears but

if range shifting is set

no zero line

 

to “0.”

sensitivity is low

gain setting.

 

if air bubbles or marine

 

 

life is clinging to the

 

 

transducer face.

 

if sediments are

 

 

present in the water.

 

if the bottom is too soft

 

 

to return an echo.

there is extreme

if the transducer is too

interference or

 

close to the engine.

noise

if the unit is properly

 

 

grounded.

3.7 Diagnostics

If you feel your unit is not working properly, conduct the diagnostic test to find the problem. If you cannot restore normal operation, contact your dealer for advice.

1.Turn on the power while pressing the [MENU/ESC] key. Continue pressing the [MENU/ESC] key until the Installation menu appears.

Installation Menu

SIMULATION

 

On

TEST ...

 

LCD PATTERN ...

 

MEMORY CLEAR

 

NMEA PORT

: In/Out

NMEA MIX

: Off

GPS WAAS*

: Off

SET BOTTOM LEVEL ..

*= Setting cannot be changed when NMEA PORT setting is "In/In."

Installation menu

2.Press▼ to choose TEST.

3.Press ► to start the test.

Level bar

 

if other echo sounders

 

 

of the same frequency

 

 

as own are being

 

 

operated nearby.

the speed/water

sensor plug.

temperature

 

 

readout is

 

 

unrealistic or not

 

 

present

 

 

the position

the connection

readout is

 

between sounder and

unrealistic or not

 

navigator.

present

navigator.

Water Temperature, Speed

Battery Voltage Temperature inside display unit

(Unit fixed at

°C.)

ROM : OK

RAM : OK

NMEA :

Temp : 68.2° F

Speed : 10.0km/h

Power : 12.4 V

Body : 39° C

Program No. 0252308-01.** Push [MENU] 3 times to exit.

** = Program version no.