1.14 Alarms

Alarm description

The LS-4100 has six conditions which generate both audio and visual alarms: bottom alarm, normal fish alarm, bottom lock fish alarm, water temperature alarm, arrival alarm and speed alarm. (The water temperature, arrival and speed alarms require appropriate sensors.)

Bottom alarm: The bottom alarm alerts you when the bottom is within the alarm range set. To activate the bottom alarm the depth must be displayed.

Fish (normal) alarm: The fish (normal) alarm tells you when fish are within the preset alarm range.

Fish (bottom lock) alarm: The fish (bottom lock) alarm, available with the bottom-lock mode, sounds when fish are within a certain distance from the bottom. Note that the bottom zoom display must be turned on to use this alarm.

Water temperature alarm: The water temperature alarm alerts when the water temperature is within (Inside alarm) the alarm range set or under/over (outside alarm) the range set.

Speed alarm: The speed alarm alerts you when the speed is within (Inside alarm) or under/over (Outside alarm) the preset speed.

Arrival alarm: The arrival alarm alerts when you are near a waypoint by the distance set.

Activating an alarm

1.Press the [MENU/ESC] key.

2.Press ▲ or ▼ to choose ALARM

MENU from page 2 on the menu.

3.Press the ► to show the ALARM menu.

 

 

 

ALARM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

 

 

 

 

 

BOTTOM

 

 

 

 

 

 

FROM

:

 

5ft

 

 

 

 

 

RANGE :

10ft

 

 

 

 

 

FISH(Normal)

: On

 

 

 

 

 

FROM

:

 

5ft

 

 

 

 

 

RANGE :

10ft

 

 

 

 

 

FISH(B/L)

: On

 

 

 

 

 

FROM

:

 

8ft

 

 

 

 

 

RANGE :

1.0ft

 

 

 

 

 

FISH LEVEL

: Medium

 

 

 

 

 

 

 

 

 

 

 

 

(1/2)

 

Page

 

 

 

 

 

 

 

 

 

 

 

 

[MENU]: Exit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

no.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inside

 

 

 

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

FROM

:

 

72.4° F

 

 

RANGE :

 

1.0° F

SPEED : Off

FROM : 0.0kt

RANGE : 1.0kt

ARRIVAL ALRM : Off

RANGE : 0.01nm

(2/2)

[MENU]: Exit

Gray characters mean alarm is inactive.

Alarm menu

4.Use ▲ or ▼ to choose an alarm as appropriate.

5.Press ► to show the options menu.

 

 

 

 

 

 

 

Off

 

 

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inside

 

 

 

 

 

 

 

 

 

 

 

 

 

On

 

 

 

 

Outside

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fish, Arrival,

Temp, Speed

Bottom Alarm

Alarm Types

On/Off

 

 

 

 

 

Alarm options

6.Use ▲ or ▼ to choose alarm type:

Off: Alarm off, On: Alarm on

Inside: Alarm generated when speed (or water temperature) is within the range set.

Outside: Alarm generated when speed (or water temperature) is outside the range set.

7.Press ◄ to close the window.

For ARRIVAL ALARM setting, skip to step 12.

11

Page 17
Image 17
Furuno Ls4100 manual Alarms, Alarm description, Activating an alarm, Alarm menu, Alarm options