Water temp/speed sensor

Connect the optional water temp/speed sensor to the XDR connector with the optional converter connector (Type 02S4147) as shown below.

Connect to XDR port at rear of display unit

MJ-A10SPF

Input data sentences (con’t)

Sentence

Meaning

MWV

Wind speed and

 

angle

RMA

Recommended

 

minimum specific

 

LORAN-C data

RMB

Recommended

 

minimum navigation

 

information

RMC

Recommended

 

minimum specific

 

GPS/TRANSIT data

MJ-A6SRMD

Tape connectors with

vulcaninzing tape and then vinyl tape to waterproof them. Bind tape ends with cable ties to prevent

From tape from unraveling. sensor

MJ-A10SRMD

From transducer

 

VHW

Water speed and

 

 

heading

 

VTG

Course over ground

 

 

and ground speed

 

XTE

Cross track error

 

Output data sentences

 

 

 

 

Sentence

Meaning

Connection of converter

connector 02S4147

4.8IEC 61162-1 Data Sentences

The tables below show the data sentences which can be input to and output from the LS-4100. The transmission speed for both input and output is 4800 bps. Data is output at two-second intervals.

Input data sentences

Sentence

Meaning

BWC

Bearing and distance to

 

waypoint

GGA

Global positioning system

 

(GPS) fix data

GLL

Geographic position -

 

latitude/longitude

HDG

Heading, deviation and variation

HDT

Heading, true

MDA

Atmospheric pressure

MTW

Water temperature

DBT (Ver. 1.5)

Depth below

 

transducer

DPT (Ver. 2.0, Ver.

Depth

3.0)

 

MTW*

Water temperature

RMB* (Ver. 2.0)

Recommended

 

minimum

 

navigation

 

information

VHW*

Water speed and

 

heading

TLL*

Target position,

 

output by [MARK]

 

key.

*= Available with connection of optional sensors/navaid

35

Page 41
Image 41
Furuno Ls4100 manual IEC 61162-1 Data Sentences, Water temp/speed sensor