7. AIS OPERATION

Dangerous target

When an AIS target violates the CPA/TCPA alarm setting (set on the ARPA 1 menu in case of ARPA or EPA menu in case of EPA) its symbol changes to the dangerous target symbol (red and flashing) and the indication “COLLISION” appears. Press the [AUDIO OFF] key to acknowledge the CPA/TCPA alarm. The audio alarm is silenced and the symbol stops flashing. Take appropriate action to avoid collision.

Thicker than activated target

Dangerous target

7.4Sleeping Targets

7.4.1Sleeping an AIS target

You may “sleep” an AIS target as below when the screen becomes filled with targets. Note that targets that have been activated automatically cannot be “slept.”

1.Use the trackball to place the cursor on an activated AIS target symbol.

2.Press the [AIS MENU] key to open the AIS menu.

3.Press the [2] key (SLEEP TARGET) to sleep the target.

4.Press any menu key to close the menu. The target is marked with the sleeping target symbol, whose triangle is smaller than that of the activated AIS target symbol.

Sleeping target

7.4.2Sleeping all AIS targets

1.Press the [AIS MENU] key to open the AIS menu.

2.Press the [8] key (SLEEP ALL TARGETS) to sleep all targets.

3.Press any menu key to close the menu.