Furuno RP-250 manual Appendix, Digital Interface IEC, Input sentences RP Board, J4, Data reception

Models: RP-250

1 73
Download 73 pages 51.81 Kb
Page 64
Image 64

APPENDIX

1. Digital Interface (IEC 61162-2)

Input sentences (RP Board, J4)

VDM, ALR, VDO

Data reception

Data is received in serial asynchronous form in accordance with the standard referenced in IEC 61162-2.

The following parameters are used:

 

 

 

 

 

 

 

Baud rate: 38400, Data bits: 8 (D7 = 0),

Parity: none, Stop bits: 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D0

D1

D2

 

D3

D4

 

D5

D6

D7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop

 

 

 

 

 

 

Data bits

 

 

 

 

bit

 

 

 

 

 

 

 

 

bit

Data sentences

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALR –Set alarm state

 

 

 

 

 

 

 

 

 

 

 

 

$AIALR,hhmmss.ss,xxx,A,A,c

--

c*hh<CR><LF>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+-----------------

 

6

 

 

 

 

 

 

 

 

 

+-----------------

 

 

5

 

 

 

 

 

 

 

 

 

+--------------------

 

 

 

4

 

 

 

 

 

 

 

 

 

+----------------------

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

+

-------------------------

 

 

 

 

2

 

 

 

 

 

 

 

 

 

+---------------------------------

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

1.Time of alarm condition change, UTC

2.Local alarm number(identifier)

3.Alarm condition(A=threshold exceeded, V=not exceeded)

4.Alarm’s acknowledge state, A=acknowledged V=unacknowledged

5.Alarm’s description text

6.Checksum

VDM – VHF data-link message

!AIVDM,x,x,x,a,s--

s,x*hh<CR><LF>

 

+-----

7

+

----- 6

 

+--------

5

 

+

------------

4

 

+

--------------

 

3

 

+----------------

 

 

2

 

+

------------------

 

 

1

 

1. Total number of sentences needed to transfer the message, 1 to 9

2. Message sentence number, 1 to 9

3. Sequential message identifier, 0 to 9

4. AIS channel Number

5. Encapsulated ITU-R M.1371 radio message

6. Number of fill-bits, 0 to 5

7. Checksum

58