Part # MCOSM06 Rev 1 (11/03/08) Page 53
MCO CONVECTION OVEN GAS VALVE

SIDE VIEW TOP VIEW

PILOT
VALVE
MAIN
VALVE
Manual
'A' Valve
Inlet
Inlet
Pressure
Tap
Regulator
Outlet
Pressure
Tap
Pilot
Outlet
Outlet
Pilot Valve
Connection
Main Valve
Connection
Common
Connection
Intermittent Pilot
Ignition Control

Specications

Regulator Adjustment Range 3 to 6" WC natural gas
5 to 12" WC propane gas
Maximum Operating Pressure 14" WC both natural & propane gas
Minimum Incoming Pressure 7" WC natural gas
14" WC propane gas