Part # MCOSM06 Rev 1 (11/03/08) Page 57
CONTROLS
Display Codes – Prompts
OFF Oven is in the OFF mode.
Lo Oven cavity temperature is below set point.
Hi Oven cavity temperature is above set point.
LOAd Oven cavity has reached set temperature - prompt for operator to load oven.
SETb Oven has defaulted to factory set back temperature.
Auto Oven is in 'auto cool down' mode and will remain in auto until cavity temp is below 150°F.
OPEn
Display will toggle from 'OPEN' to 'DOOR' to prompt for operator to open door when unit is in cool down.
Door
Door In auto cool down mode, door is open past 30° or in cooking mode, door is opened.
Prob Open or shorted cavity sensing probe.
HELP Oven cavity has exceeded 560°F.
CodE 475 controllers, prompt for operator to enter access code from programming 4-2-7-5.
SHLF 475 controllers, prompt for operator to select shelf to be programmed.
PR-2 475 controllers, prompt for operator to program the prole for the second cook time if required.
PRE 475 controllers, prompt for operator to set pre-alarm if required.
HoLd 475 controllers, prompt for operator set the hold temperature the oven is in programmed HOLD
temperature.
FAn 475 controller, prompt for operator to se fan speed.
DonE Oven has completed its cooking cycle.
CooL Door is open less then 30° in cool down mode.