PROBE CALIBRATION

GARLAND ELECTRIC CLAMSHELL GRILL WITH PRODUCT RECOGNITION MODEL MWE3W

INSTALLATION/OPERATION MANUAL

PROBE CALIBRATION

Monthly Calibration of Grill Temperature Zones

Tools: Digital Pyrometer with Surface Probe

Warning: PERSONAL INJURY FROM BURNS MAY RESULT WHEN COMING IN CONTACT WITH HOT COOKING SURFACES.

NOTE: Calibration of grills is done with release material sheets “OFF”.

PLEASE FOLLOW THESE INSTRUCTIONS EXACTLY AS THEY APPEAR BELOW:

1.The upper platens and lower grill plate should be at operating temperatures to perform this calibration

procedure. Press the or button to select a “CLAM” operation and allow the grill to reach the set temperature and stabilize, (approximately 30 minutes).

7.PRESS the Monthly Calibration of Grill Temperature Zones button to lock the calibrated temperature into the controller.

8.Press the PLEASE FOLLOW THESE INSTRUCTIONS EXACTLY AS THEY APPEAR BELOW: or THERMOCOUPLE LOCATIONS button to select the next heat zone.

9.Move the pyrometer’s surface probe to the newly selected heat zone and repeat steps 5, 6, and 7.

10.Repeat the procedure for each of the heat zones.

11.Continue to cycle through each heat zone repeating the sequence until all temperatures are within 1°.

12.Exit the program mode by pressing the Manual background button 2x. The controller will return to its previous state in the Normal Operating Mode.

THERMOCOUPLE LOCATIONS

2.PRESS and HOLD the Manual background button for approximately

3 seconds, or until the controller will displays: “PROBE CAL”.

3.PRESS the Manual background button to display the first temperature zone to be calibrated. The first zone to be calibrated is “FRONT TEMP CAL”. The zones are displayed in order of

FRONT TEMP CAL, MIDDLE TEMP CAL, BACK TEMP CAL, TOP TEMP CAL.

9.360

 

 

11.500

 

 

[292mm]

 

 

5.750

 

 

[146mm]

[238mm]

(FROM FRONT

OF PLATEN)

PLATEN THERMOCOUPLE

LOCATIONS (VIEW FROM BOTTOM)

MWE3W: The electric grill’s thermocouple probes are located front to rear, as shown in the diagram to the right. Each upper platen has one thermocouple in the center.

MWG3W: The gas grill’s thermocouple probes are located in the center of each lane, as shown in the diagram to the right. Each upper platen has one thermocouple in the center.

4.Select a heat zone display using the Manual background or Manual background buttons.

5.Allow at least 5 seconds for the pyrometer to respond and stabilize. Note the temperature on the pyrometer.

6.If the temperature on the grill control display does not match the temperature on the pyrometer, adjust the

temperature on the grill control accordingly. The Manual background button will increase the displayed temperature in one,

(1) degree increments. The Manual background button will decrease the displayed temperature in one, (1), degree Increments.

 

 

 

 

36.000

 

 

 

 

 

[914mm]

 

 

 

 

 

18.000

 

 

 

 

 

[457mm]

 

19.732

[501mm]

[325mm]

 

 

 

 

12.814

[150mm]

 

 

 

 

5.896

 

 

 

 

 

6.110

FRONT

6.110

 

 

 

OF GRILL

 

 

 

[155mm]

[155mm]

 

 

 

 

24.000

[610mm]

NOTE: During step 6, the control should be sounding a high-pitched tone. The temperature can only be adjusted if this tone is sounding. If the control is silent, the temperature will not change.

PART #4521777 (03/19/08)