Magnum 6K25 Managed Fiber Switch | Installation and User Guide (04/06) |
Caution: Be careful not to disturb the power supply.
Looking down into the Magnum 6K25 unit, notice that there are individual PM installation spaces and female latch(white) connectors provided on the main board along with four
Figure 3.5.1b: Magnum 6k25, Top view without chassis cover
Step 3. Remove front panel face plate retaining screws
There are four PM slots (A, B, C and D) located on the front of the chassis cover. Looking into the vertical placed Chassis cover of the unit, there are three brackets with retaining screws (#256 flat head ) which hold each PM Face plate card slot securely. These six screws shown in the picture below are used to secure a PM face plate in position, but unscrew only four of the screws as shown in Fig. below. These screws are also used to secure the individual 6KPM cards screen plate which can be subjected to significant forces from the attached cables. (See Figure 3.5.1c)
Figure 3.5.1c: Top View – 6KPM retaining screws hold Face Plate
3.5.2Installing 6KPM Cards in the Magnum 6K25
Up to four
Step 1. Remove top chassis cover. See procedure in Section 3.5.1 above.