
  | Magnum   | 
  | Installation and User Guide  | (04/07)  | 
  | |||||||||||
  | Fiber  | Speed,  | 
  | Std.  | Wave  | Cable  | X’mitr  | R’cvr | Worst  | Worst*  | 
  | typical  | typical*  | |||
  | Port  | Std.  | Mode  | km  | -  | Size  | Output  | Sens.  | OPB,  | distance  | 
  | OPB,  | 
  | distance  | ||
Module  | 
  | fdx  | length  | µm  | PT , dB  | PR ,dB  | dB  | Km, fdx  | 
  | dB  | 
  | Km, fdx  | ||||
  | 
  | 
  | 
  | |||||||||||||
  | 
  | 
  | 
  | (hdx)  | nm  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
6KP4V- | 10Mb  | Multi-  | 2  | 850  | 62.5/125  | 
  | 14  | 5  | 
  | 17  | 
  | 6  | 
  | |||
  | F10ST  | FL  | Mode  | (2)  | 
  | 100/140  | 
  | 19.5  | 5.9  | 
  | 23.5  | 
  | 7  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 50/125  | 
  | 19.5  | 3.4  | 
  | 13.5  | 
  | 4.8  | 
  | ||
  | 6KPV- | 100Mb | Multi-  | 2  | 1300  | 62.5/125  | 
  | 9.0  | 3.0  | 
  | 14  | 
  | 5  | 
  | ||
MST, MSC  | FX  | mode  | (0.4)  | 
  | 50/125  | 
  | 5.5  | 2.0  | 
  | 12  | 
  | 4  | 
  | |||
100Mb  | Single-  | 18+  | 1300  | 9/125  | 
  | 14  | 28  | 
  | 17.5  | 
  | 35  | 
  | ||||
FX  | mode  | (0.4)  | 
  | 
  | 
  | 
  | ||||||||||
  | 6KPV-  | 100Mb  | Single-  | 40  | 1300  | 9/125  | 
  | 29  | 58  | 
  | 32.5  | 
  | 65  | 
  | ||
  | FX  | mode  | (0.4)  | 
  | 
  | 
  | 
  | |||||||||
  | SSCL  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 6KPV-  | 100Mb  | Multi-  | 2  | 1300  | 62.5/125  | 
  | 9.0  | 3.0  | 
  | 15.8  | 
  | 5.5  | 
  | ||
  | MTRJ  | FX  | mode  | (0.4)  | 
  | 50/125  | 
  | 5.5  | 2.0  | 
  | 12.2  | 
  | 4.0  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 6KPV-  | 100Mb  | Multi-  | 2  | 1300  | 62.5/125  | 
  | 12  | 4  | 
  | 16  | 
  | 5.7  | 
  | ||
  | FX  | mode  | (0.4)  | 
  | 
  | 
  | 
  | |||||||||
  | MLC  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
100Mb  | Single-  | 15+  | 1310  | 9/125  | 
  | 11  | 22  | 
  | -  | 
  | -  | 
  | ||||
FX  | Mode  | (0.4)  | 
  | 
  | 
  | 
  | ||||||||||
  | GBIC-  | 1000Mb  | Multi-  | 0.55  | 850  | 62.5/125  | 
  | 5.5  | 2  | 
  | 12.5  | 
  | 4  | 
  | ||
  | 
  | mode  | 
  | 
  | 
  | 
  | 
  | |||||||||
  | SXSC  | 
  | 
  | 
  | 50/125  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | GBIC-  | 1000Mb  | Single-  | 10  | 1300  | 9/125  | 
  | 8.5  | 17  | 
  | 10.5  | 
  | 21  | 
  | ||
  | 
  | mode  | 
  | 
  | 
  | 
  | 
  | |||||||||
LXSC10  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | GBIC-  | 1000Mb  | Single-  | 25  | 1550  | 9/125  | 
  | 15  | 37.5  | 
  | 17.5  | 
  | 43  | 
  | ||
  | 
  | mode  | 
  | 
  | 
  | 
  | 
  | |||||||||
LXSC25  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | GBIC-  | 1000Mb  | Single-  | 40  | 1550  | 9/125  | 
  | 15  | 60  | 
  | 17.5  | 
  | 70  | 
  | ||
  | 
  | mode  | 
  | 
  | 
  | 
  | 
  | |||||||||
ZXSC40  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | GBIC-  | 1000Mb  | Single-  | 70  | 1550  | 9/125  | 
  | 18  | 90  | 
  | 20.5  | 
  | 102  | 
  | ||
  | 
  | mode  | 
  | 
  | 
  | 
  | 
  | |||||||||
ZXSC70  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
*Note: The use of either 
•The 100Mb fiber segment must operate in 
•The 
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
www . GarrettCom . com
48