www.gateway.com

Miscellaneous messages

Keyboard Error

Keyboard is not present or the hardware is not responding when the keyboard controller is initialized.

Keyboard/Interface Error

Keyboard Controller failure. This may indicate a problem with system hardware.

System Halted

The system has been halted. A reset or power cycle is required to reboot the machine. This message appears after a fatal error has been detected.

Understanding sensors and sensor readings

Sensor type codes

The following section lists the sensors supported by the BMC, including type, name, status, and current reading. The status and current reading information is for example only.

Sensor type

Sensor name

Sensor status

Current reading

 

 

 

 

Sys. ACPI Pwr State

ACPI State

Normal

5

 

 

 

 

Module/Board

System Reset

State Deasserted

0

 

 

 

 

Fan

SYS FAN 1

Normal operating

2362.39 RPM

 

 

range

 

Fan

SYS FAN 2

Normal operating

1771.79 RPM

 

 

range

 

 

 

 

 

Voltage

System 12V

Normal operating

12.04 Volts

 

 

range

 

Voltage

System 5V

Normal operating

5.0652 Volts

 

 

range

 

 

 

 

 

Voltage

System 5V STBY

Normal operating

4.9848 Volts

 

 

range

 

Voltage

System 3.3V

Normal operating

3.4026 Volts

 

 

range

 

 

 

 

 

Voltage

VTT CPU

Normal operating

1.1931 Volts

 

 

range

 

Voltage

VCORE 0

Normal operating

1.2901 Volts

 

 

range

 

 

 

 

 

Voltage

VCORE 1

Normal operating

1.2901 Volts

 

 

range

 

Voltage

VTT MEM

Normal operating

0.8924 Volts

 

 

range

 

 

 

 

 

Voltage

1.5V NB

Normal operating

1.4841 Volts

 

 

range

 

Voltage

1.9V PHY

Normal operating

1.9206 Volts

 

 

range

 

 

 

 

 

65