membrane element housings for removal and loading of membrane elements. If 114 cm (45-inches) are not available, the entire membrane element housing may need to be removed for membrane element replacement.

2.3Plumbing

The E4H-CE and E8-CE come with flanged connections installed on all isolation valves.

Table 2.5

Connections

MACHINE

E4H-CE

E8-CE

E8-CE

E8-CE

 

 

 

 

 

Model

All Models

9 - 14

17 - 23

28 - 45

 

 

 

 

 

Inlet

40 mm

50 mm

80 mm

100 mm

 

 

 

 

 

Concentrate

25 mm

40 mm

40 mm

50 mm

 

 

 

 

 

Permeate

25 mm

50 mm

50 mm

80 mm

 

 

 

 

 

2.4Power and Electrical Requirements

WARNING: BEFORE OBTAINING ACCESS TO TERMINALS, ALL SUPPLY CIRCUITS MUST BE DISCONNECTED.

IMPORTANT NOTE: Motor are dual rated. Factory installed starters and wiring are for 400VAC (380VAC). Motor starter and motor wiring must be replaced prior to converting to lower voltage. Custom Factory Order (CFO) based motors can be rated at other voltages. Check motor for rating.

The E4H-CE and E8-CE machines are supplied with a single source of incoming power. This power can be 230, 380, 415, 460, or 575 VAC. Check tag on High Voltage Enclosure to verify which voltage is required. The power for control is transformed down from the three-phase power at the main disconnect to 230 single-phase and then down to 24 VDC.

For each model, the motor is wired at the factory to an overload protection motor starter, which is controlled by the panel-mounted Operator Interface Terminal (OIT).