membrane element housings for removal and loading of membrane elements. If 114 cm
2.3Plumbing
The
Table 2.5
Connections
MACHINE |
|
| ||
|
|
|
|
|
Model | All Models | 9 - 14 | 17 - 23 | 28 - 45 |
|
|
|
|
|
Inlet | 40 mm | 50 mm | 80 mm | 100 mm |
|
|
|
|
|
Concentrate | 25 mm | 40 mm | 40 mm | 50 mm |
|
|
|
|
|
Permeate | 25 mm | 50 mm | 50 mm | 80 mm |
|
|
|
|
|
2.4Power and Electrical Requirements
WARNING: BEFORE OBTAINING ACCESS TO TERMINALS, ALL SUPPLY CIRCUITS MUST BE DISCONNECTED.
IMPORTANT NOTE: Motor are dual rated. Factory installed starters and wiring are for 400VAC (380VAC). Motor starter and motor wiring must be replaced prior to converting to lower voltage. Custom Factory Order (CFO) based motors can be rated at other voltages. Check motor for rating.
The
For each model, the motor is wired at the factory to an overload protection motor starter, which is controlled by the
11