TROUBLESHOOTING
SYMPTOM | POSSIBLE CAUSES | REMEDIES |
|
|
|
High operating pressure | Recycle or concentrate valve | Disassemble the plumbing |
| plugged | to the recycle valve and |
|
| remove foreign particles. |
|
| Check the concentrate |
|
| valve stem. |
|
|
|
| Inaccurate pressure gauge | Replace or calibrate the |
|
| gauge as required. |
|
|
|
| Restricted flow after pump | Check for blockage of the |
| outlet | concentrate flow at the |
|
| inlets and outlets of the |
|
| membrane element |
|
| housings. |
|
|
|
| Telescoped membrane ele- | Ensure that the |
| ment covering membrane ele- | scoping device (ATD) is |
| ment housing outlet port | located properly on the |
|
| membrane elements. |
|
|
|
Water flowing when | Inlet solenoid valve not clos- | Clean or replace the valve. |
machine is turned OFF | ing or seating properly | Clean the membrane ele- |
|
| ments with detergent |
|
| immediately. Water must |
| Severely fouled or dirty | not pass through the inlet |
| membrane elements | when the machine is OFF. |
|
|
|
Declining rejection (high | Dirty or fouled membrane | Flush and clean the mem- |
permeate conductivity) | elements | brane elements. |
|
|
|
28