GE 000 gpd to 288 manual Possible Causes, Remedies, High operating pressure, Water flowing when

Models: 000 gpd to 288 E4H-CE Series, E8-CE Series 000 gpd

1 45
Download 45 pages 17.31 Kb
Page 33
Image 33
POSSIBLE CAUSES

TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSES

REMEDIES

 

 

 

High operating pressure

Recycle or concentrate valve

Disassemble the plumbing

 

plugged

to the recycle valve and

 

 

remove foreign particles.

 

 

Check the concentrate

 

 

valve stem.

 

 

 

 

Inaccurate pressure gauge

Replace or calibrate the

 

 

gauge as required.

 

 

 

 

Restricted flow after pump

Check for blockage of the

 

outlet

concentrate flow at the

 

 

inlets and outlets of the

 

 

membrane element

 

 

housings.

 

 

 

 

Telescoped membrane ele-

Ensure that the anti-tele-

 

ment covering membrane ele-

scoping device (ATD) is

 

ment housing outlet port

located properly on the

 

 

membrane elements.

 

 

 

Water flowing when

Inlet solenoid valve not clos-

Clean or replace the valve.

machine is turned OFF

ing or seating properly

Clean the membrane ele-

 

 

ments with detergent

 

 

immediately. Water must

 

Severely fouled or dirty

not pass through the inlet

 

membrane elements

when the machine is OFF.

 

 

 

Declining rejection (high

Dirty or fouled membrane

Flush and clean the mem-

permeate conductivity)

elements

brane elements.

 

 

 

28

Page 33
Image 33
GE 000 gpd to 288 manual Possible Causes, Remedies, High operating pressure, Water flowing when, machine is turned OFF