Quick Reference

2500 Series Cooling with Electric Heat

MODEL

COOLING

Cooling

 

Electric Heat

Electric

Electric

Min. Circuit

NUMBER

(Btuh)

Watts

EER

(Btuh)

Heater

Heat

Protection

 

 

 

 

 

Watts

Amps

(Amps)

AZ25E07D2*

7100/6900

600/585

11.8/11.8

8600/7100

2550/2090

11.0/10.0

15

AZ25E07D3*

7100/6900

600/585

11.8/11.8

11700/9600

3450/2820

15.0/13.6

20

AZ25E09D2*

9000/8800

785/765

11.5/11.5

8600/7100

2550/2090

11.0/10.0

15

AZ25E09D3*

9000/8800

785/765

11.5/11.5

11700/9600

3450/2820

15.0/13.6

20

AZ25E09D5*

9000/8800

785/765

11.5/11.5

17000/13900

5000/4090

21.7/19.7

30

AZ25E12D2*

11700/11500

1075/1055

10.9/10.9

8600/7100

2550/2090

11.0/10.0

15

AZ25E12D3*

11700/11500

1075/1055

10.9/10.9

11700/9600

3450/2820

15.0/13.6

20

AZ25E12D5*

11700/11500

1075/1055

10.9/10.9

17000/13900

5000/4090

21.7/19.7

30

AZ25E15D2*

14600/14300

1520/1490

9.6/9.6

8600/7100

2550/2090

11.0/10.0

15

AZ25E15D3*

14600/14300

1520/1490

9.6/9.6

11700/9600

3450/2820

15.0/13.6

20

AZ25E15D5*

14600/14300

1520/1490

9.6/9.6

17000/13900

5000/4090

21.7/19.7

30

AZ25E07E3*

7100

600

11.8

8600

2550

9.6

15

AZ25E07E4*

7100

600

11.8

12600

3700

14.0

20

AZ25E09E3*

9000

785

11.5

8600

2550

9.6

15

AZ25E09E4*

9000

785

11.5

12600

3700

14.0

20

AZ25E09E5*

9000

785

11.5

17000

5000

18.9

30

AZ25E12E3*

11700

1075

10.9

8600

2550

9.6

15

AZ25E12E4*

11700

1075

10.9

12600

3700

14.0

20

AZ25E12E5*

11700

1075

10.9

17000

5000

18.9

30

AZ25E15E3*

14600

1520

9.6

8600

2550

9.6

15

AZ25E15E4*

14600

1520

9.6

12600

3700

14.0

20

AZ25E15E5*

14600

1520

9.6

17000

5000

18.9

30

2500 and 3500 Series

Control Panel

3500 Series Heat Pump with Backup Resistance Heat

MODEL

COOLING

Cooling

 

Reverse

 

Electric Heat

Electric

Electric

Min. Circuit

NUMBER

(Btuh)

Watts

EER

Cycle Heat

COP

(Btuh)

Heater

Heat

Protection

 

 

 

 

(Btuh)

 

 

Watts

Amps

(Amps)

AZ35H07D2*

7100/6900

600/585

11.8/11.8

6400/6200

3.5/3.5

8600/7100

2550/2090

11.0/10.0

15

AZ35H07D3*

7100/6900

600/585

11.8/11.8

6400/6200

3.5/3.5

11700/9600

3450/2820

15.0/13.6

20

AZ35H09D2*

9000/8800

785/765

11.5/11.5

8400/8200

3.5/3.5

8600/7100

2550/2090

11.0/10.0

15

AZ35H09D3*

9000/8800

785/765

11.5/11.5

8400/8200

3.5/3.5

11700/9600

3450/2820

15.0/13.6

20

AZ35H09D5*

9000/8800

785/765

11.5/11.5

8400/8200

3.5/3.5

17000/13900

5000/4090

21.7/19.7

30

AZ35H12D2*

11700/11500

1075/1055

10.9/10.9

10900/10700

3.3/3.3

8600/7100

2550/2090

11.0/10.0

15

AZ35H12D3*

11700/11500

1075/1055

10.9/10.9

10900/10700

3.3/3.3

11700/9600

3450/2820

15.0/13.6

20

AZ35H12D5*

11700/11500

1075/1055

10.9/10.9

10900/10700

3.3/3.3

17000/13900

5000/4090

21.7/19.7

30

AZ35H15D2*

14600/14300

1520/1490

9.6/9.6

13400/13200

3.1/3.1

8600/7100

2550/2090

11.0/10.0

15

AZ35H15D3*

14600/14300

1520/1490

9.6/9.6

13400/13200

3.1/3.1

11700/9600

3450/2820

15.0/13.6

20

AZ35H15D5*

14600/14300

1520/1490

9.6/9.6

13400/13200

3.1/3.1

17000/13900

5000/4090

21.7/14.7

30

AZ35H07E3*

7100

600

11.8

6400

3.5

8600

2550

9.6

15

AZ35H07E4*

7100

600

11.8

6400

3.5

12600

3700

14.0

20

AZ35H09E3*

9000

785

11.5

8400

3.5

8600

2550

9.6

15

AZ35H09E4*

9000

785

11.5

8400

3.5

12600

3700

14.0

20

AZ35H09E5*

9000

785

11.5

8400

3.5

17000

5000

18.9

30

AZ35H12E3*

11700

1075

10.9

10900

3.3

8600

2550

9.6

15

AZ35H12E4*

11700

1075

10.9

10900

3.3

12600

3700

14.0

20

AZ35H12E5*

11700

1075

10.9

10900

3.3

17000

5000

18.9

30

AZ35H15E3*

14600

1520

9.6

13400

3.1

8600

2550

9.6

15

AZ35H15E4*

14600

1520

9.6

13400

3.1

12600

3700

14.0

20

AZ35H15E5*

14600

1520

9.6

13400

3.1

17000

5000

18.9

30

COP –

LEGEND

All Units are 60 hertz single phase.

Coefficient of Performance

Dual rated 230/208 volt units are shown with ratings separated by “/”.

EER –

Energy Efficient Ratio

Units with one rating are 265 volt units.

*– Covers All Model Versions

2

Page 2
Image 2
GE 5500 manual Quick Reference, Series Control Panel, Series Cooling with Electric Heat

5500 specifications

The GE 5500 is a sophisticated gas turbine that represents a benchmark in the realm of power generation technology. Known for its impressive performance and efficiency, the GE 5500 has garnered attention in various industries, particularly in energy production. Designed for combined-cycle applications, this turbine effectively leverages both gas and steam cycles to optimize electricity generation.

One of the standout features of the GE 5500 is its advanced aerodynamics, which enhance the efficiency of the combustion process. The turbine employs state-of-the-art combustion technology that allows for high operational flexibility and minimizes emissions, meeting stringent environmental standards. This is particularly important in today’s energy landscape, where sustainability is a crucial focus.

The GE 5500 is equipped with a robust control system that utilizes digital twin technology. This innovative approach allows operators to simulate and analyze the performance of the turbine virtually, leading to improved operational efficiency and reduced downtime. Additionally, this turbine features an integrated health monitoring system that provides real-time data on performance metrics, allowing for predictive maintenance and enhancing overall reliability.

The materials used in the construction of the GE 5500 are engineered to withstand high temperatures and stress levels, ensuring longevity and durability. This includes high-performance alloys that maintain structural integrity even under extreme operating conditions.

Installation and maintenance of the GE 5500 are streamlined through its modular design, which simplifies access to components and reduces service time. This efficiency translates into lower operational costs, making the GE 5500 an economically favorable choice for utilities and independent power producers.

Furthermore, the GE 5500 can be integrated into a variety of power plant configurations, whether for peaking power or baseload operations, which adds to its versatility. Its ability to quickly ramp up production makes it particularly valuable in an energy market characterized by fluctuating demand.

Overall, the GE 5500 gas turbine is a remarkable engineering feat that combines cutting-edge technology with practical design. Its efficiency, reliability, and adaptability position it as a leading choice for power generation needs, meeting the requirements of modern energy systems while contributing to a more sustainable future.