Maximum Connected Load For Deluxe Series (2500 and 3500)

The maximum connected load of a Zoneline unit occurs when the unit is in resistance heating operation. The maximum amperage shown in the tables below is the combined total of the resistance heater and the indoor fan motor.

Model

230 V

 

208 V

 

Number

Watts

 

Amps

Watts

 

Amps

AZ25E07D2*

2600

 

11.4

2130

 

10.2

AZ25E07D3*

3500

 

15.3

2860

 

13.8

AZ25E09D2*

2610

 

11.4

2140

 

10.3

AZ25E09D3*

3510

 

15.3

2870

 

13.9

AZ25E09D5*

5060

 

22.0

4140

 

20.0

AZ25E12D2*

2620

 

11.5

2150

 

10.3

AZ25E12D3*

3520

 

15.4

2880

 

13.9

AZ25E12D5*

5070

 

22.1

4150

 

20.0

AZ25E15D2*

2630

 

11.5

2160

 

10.4

AZ25E15D3*

3520

 

15.4

2890

 

14.0

AZ25E15D5*

5080

 

22.1

4160

 

20.1

AZ35H07D2*

2600

 

11.4

2130

 

10.2

AZ35H07D3*

3500

 

15.3

2860

 

13.8

AZ35H09D2*

2610

 

11.4

2140

 

10.3

AZ35H09D3*

3510

 

15.3

2870

 

13.9

AZ35H09D5*

5060

 

22.0

4140

 

20.0

AZ35H12D2*

2620

 

11.5

2150

 

10.3

AZ35H12D3*

3510

 

15.4

2880

 

13.9

AZ35H12D5*

5070

 

22.1

4150

 

20.0

AZ35H15D2*

2630

 

11.5

2160

 

10.4

AZ35H15D3*

3530

 

15.4

2890

 

14.0

AZ35H15D5*

5080

 

22.1

4160

 

20.1

Model

265 V

 

Number

Watts

 

Amps

AZ25E07E3*

2600

 

9.8

AZ25E07E4*

3750

 

14.3

AZ25E09E3*

2610

 

9.9

AZ25E09E4*

3760

 

14.3

AZ25E09E5*

5060

 

19.2

AZ25E12E3*

2620

 

9.9

AZ25E12E4*

3770

 

14.3

AZ25E12E5*

5070

 

19.2

AZ25E15E3*

2630

 

9.9

AZ25E15E4*

3780

 

14.3

AZ25E15E5*

5080

 

19.2

AZ35H07E3*

2600

 

9.8

AZ35H07E4*

3750

 

14.3

AZ35H09E3*

2610

 

9.9

AZ35H09E4*

3760

 

14.3

AZ35H09E5*

5060

 

19.2

AZ35H12E3*

2620

 

9.9

AZ35H12E4*

3770

 

14.3

AZ35H12E5*

5070

 

19.2

AZ35H15E3*

2630

 

9.9

AZ35H15E4*

3780

 

14.3

AZ35H15E5*

5080

 

19.2

Maximum Connected Load For Premium Series (5500) 230/208 V

Model

With RAK3152

With RAK3202

With RAK3302

Number

Watts/Amps

Watts/Amps

Watts/Amps

 

230V

208V

230V

208V

230V

208V

AZ55H07DA*

2615/11.4

2145/10.3

3515/15.3

2880/13.9

3515/15.3**

2880/13.9**

AZ55H09DA*

2615/11.4

2145/10.3

3515/15.3

2880/13.9

5065/22.0

4150/20.0

AZ55H12DA*

2640/11.5

2165/10.4

3540/15.4

2900/14.0

5090/22.1

4170/20.1

AZ55H15DA*

2685/11.7

2210/10.6

3585/15.6

2945/14.2

5135/22.3

4215/20.3

Maximum Connected Load For Premium Series (5500) 265V

Model

With RAK5152***

With RAK5172

With RAK5202

With RAK5302

Number

Watts/Amps

Watts/Amps

Watts/Amps

Watts/Amps

AZ55H07EA*

2235/8.6

3075/11.6

3775/14.3

3775/14.3**

AZ55H09EA*

2400/9.1

3075/11.6

3775/14.3

5075/19.2

AZ55H12EA*

2670/10.3

3100/11.7

3800/14.4

5100/19.3

AZ55H15EA*

2965/11.4

3135/11.8

3835/14.5

5135/19.4

*Covers all model versions.

**AZ55H07 does not have 5 kW heater.

***Maximum connected load occurs when this unit with this power connection kit is in simultaneous operation of heat pump with supplemental 1700 watt heater.

44

Page 44
Image 44
GE 5500 manual Maximum Connected Load For Deluxe Series 2500

5500 specifications

The GE 5500 is a sophisticated gas turbine that represents a benchmark in the realm of power generation technology. Known for its impressive performance and efficiency, the GE 5500 has garnered attention in various industries, particularly in energy production. Designed for combined-cycle applications, this turbine effectively leverages both gas and steam cycles to optimize electricity generation.

One of the standout features of the GE 5500 is its advanced aerodynamics, which enhance the efficiency of the combustion process. The turbine employs state-of-the-art combustion technology that allows for high operational flexibility and minimizes emissions, meeting stringent environmental standards. This is particularly important in today’s energy landscape, where sustainability is a crucial focus.

The GE 5500 is equipped with a robust control system that utilizes digital twin technology. This innovative approach allows operators to simulate and analyze the performance of the turbine virtually, leading to improved operational efficiency and reduced downtime. Additionally, this turbine features an integrated health monitoring system that provides real-time data on performance metrics, allowing for predictive maintenance and enhancing overall reliability.

The materials used in the construction of the GE 5500 are engineered to withstand high temperatures and stress levels, ensuring longevity and durability. This includes high-performance alloys that maintain structural integrity even under extreme operating conditions.

Installation and maintenance of the GE 5500 are streamlined through its modular design, which simplifies access to components and reduces service time. This efficiency translates into lower operational costs, making the GE 5500 an economically favorable choice for utilities and independent power producers.

Furthermore, the GE 5500 can be integrated into a variety of power plant configurations, whether for peaking power or baseload operations, which adds to its versatility. Its ability to quickly ramp up production makes it particularly valuable in an energy market characterized by fluctuating demand.

Overall, the GE 5500 gas turbine is a remarkable engineering feat that combines cutting-edge technology with practical design. Its efficiency, reliability, and adaptability position it as a leading choice for power generation needs, meeting the requirements of modern energy systems while contributing to a more sustainable future.