GE 183D5580P249 Troubleshooting Tips Consumer Support, Gas Supply Requirements, Instructions

Models: 183D5580P249 49-85167-1 04-09 JR C2S980

1 64
Download 64 pages 46.44 Kb
Page 43
Image 43
 Gas Supply Requirements

Read these instructions completely and carefully.

Recommended Gas Pipe Outlet LocationsProvide Adequate Gas SupplyTroubleshooting Tips Consumer Support Gas Supply Requirements

Recommended Gas Pipe Outlet Locations

NOTE: Make gas connections on the left side of the cutout opening.

30

3

Recommendedarea for through-the-wall

3

 

 

connectionof pipe stub/shut-offvalve.

 

 

9

 

 

 

 

 

This area allows flush installation to rear wall.

7-1/2

2

Recommended area for through-the-floorconnection of pipe stub/shut-off valve.

Provide Adequate Gas Supply

Your range is designed to operate at a pressure of 5 of water column on natural gas or, if designed for LP gas (propane or butane), 10 of water column.

Safety Instructions Operating Instructions

Instructions

Installation

 

 

Make sure you are supplying your range with the type of gas for whichit is designed.

This rangeis convertible for use on naturalor propanegas. If you decide to use this rangeon LP gas, conversion must be made by a qualified LP installerbefore attempting to operatethe rangeon that gas.

For proper operation, the pressure of natural gas supplied to the regulator must be between 5 and 13 of water column.

For LP gas, the pressure suppliedmust be between 10 and 13 of water column.

When checking for proper operation of the regulator, the inlet pressure must be at least 1 greater than the operating (manifold) pressure as given above.

The pressureregulator located at the inlet of therange manifoldmustremain inthe supplylineregardless of whether naturalor LP gasisbeingused.

A flexible metal appliance connector used to connect the range to the gas supply line should have an I.D. of 1/2 and be 5 feet in length for ease of installation. In Canada, flexible connectors must be single wall metal connectors no longer than

6 feet in length.

Troubleshooting Tips Consumer Support

43

Page 43
Image 43
GE 183D5580P249 Troubleshooting Tips Consumer Support, Gas Supply Requirements, Provide Adequate Gas Supply, Instructions