 Anti-Tip Device Installation

Instructions

Installationof the range.

When All Hookups Are Completed:Manual backgroundManual background Anti-Tip Device Installation

Operating Instructions Safety

To reduce the risk of tipping the range, the range must be secured by a properly installed anti-tip bracket. See installation instructions shipped with the bracket for complete details before attempting to install.

To check if the bracket is installed and engaged properly, remove the storage drawer or kick panel and look underneath the range to see that the leveling leg is engaged in the bracket. On models without a storage drawer or kick panel, carefully tip the range forward. The bracket should stop the range within 4 inches. If it does not, the bracket must be reinstalled. If the range is pulled from the wall for any reason, always repeat this procedure to verify the range is properly secured by the anti-tip bracket.

For free-standing or slide-in ranges, never completely remove the leveling legs or the range will not be secured to the anti-tip device properly.

If you did not receive an anti-tip bracket with your purchase, call 1.800.626.8774 to receive one at no cost (in Canada, call 1.800.561.3344). For installation instructions of the bracket, visit GEAppliances.com (in Canada, GEAppliances.ca).

Installation

Instructions

 

 

Consumer Support Troubleshooting Tips

When All Hookups Are Completed:

MAKE SURE ALL CONTROLS ARE LEFT IN THE

MAKE SURE THE FLOW OF COMBUSTION

OFF POSITION.

AND VENTILATION AIR TO THE RANGE IS

 

UNOBSTRUCTED.

Converting to LP Gas (or converting back to natural gas from LP)

This range leaves the factoryset for use with natural

The conversion instructions and LP orifices can

gas. If you want to convertto LP gas, the conversion

be foundattached to the range next to the

must be performed by a qualified LP gas instaler.

pressureregulator.

 

Keep these instructions and the orifices in case

 

you want to convert back to natural gas.