Read these instructions completely and carefully.
Replace the Power Cord (Optional) (Continued)
Perform this step only if the power cord shipped on the range does not matchyour wallreceptacle.
3-Wire Power Cord Installation Option
Safety Instructions
WARNING: The neutral or ground wire of the power cord must be connected to the neutral terminal locatedin the centerof the terminal block. The powerleads must be connected to the lowerleft and the lower right terminals of the terminal block.
Locate the copper ground strap on the lower back of the range.
Loosen the upper center screw on the terminal block.
Slide the open slotted end of the ground strap underthe upper center screw on the terminal block. Make sure the ground strapis all the way against the upper center screw and tighten it in place.
Place the ground plate (removed earlier) over the bottom of the ground strap,press them against the range frame and attachthem with the ground screw (removed earlier).
Insert the new power cord through the strain relief. Allow enough slack to easilyattachthe wires to the terminal block.
Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lowerposition of the terminal block. Tighten screws securely (approximately 20
Secure the strain reliefin placein the bracket by tightening the strain relief screws.
| Terminalblock |
| (appearance |
| may vary) |
| Neutral |
| terminal |
Ground |
|
plate | Ground strap |
Power cord
Groundstrap
Open slottedend