Installation
Hot Water Connection
The hot water connection is located at the lower
1.The size of the incoming hot water line should be 3/4" or larger.
2.The PRV should be adjusted to supply a minimum flowing pressure of 20 PSI/138 kPA during the final rinse. The maximum flowing pressure must not exceed 25 PSI/172 kPa during the final rinse.
3.The temperature of the incoming hot water must maintain a minimum temperature of 140°F/60°C for a 40°F/22°C rise booster or a minimum temperature of 110°F/43°C for a 70°F/39°C rise booster.
4.A manually operated 3/4" or larger
Drain Connection
The drain water connection is a 2"
1.The dishwasher drain is 2" O.D. hose connection.
2.A optional drain water tempering kit is available (consult the factory).
3.Drain water flow is controlled by an automatic electrically operated drain valve.
4.The floor sink and/or drain plumbing must be able to accommodate a maximum drain flow rate of
20 US gpm / 17 Imp gpm / 76 Lpm.
The incoming hot water line is a 3/4" NPT connection.
The drain is a 2"
NOTE:
Plumbing connections must comply with all national and/or local plumbing and sanitary codes.
6