GE DH2000 operation manual Hot Water Connection, Drain Connection, Installation

Models: DH2000

1 44
Download 44 pages 62.8 Kb
Page 14
Image 14
Hot Water Connection

Installation

Hot Water Connection

The hot water connection is located at the lower left-rear side of the dishwasher. A 3/4" line strainer and pressure regulating valve (PRV) were installed at the factory.

1.The size of the incoming hot water line should be 3/4" or larger.

2.The PRV should be adjusted to supply a minimum flowing pressure of 20 PSI/138 kPA during the final rinse. The maximum flowing pressure must not exceed 25 PSI/172 kPa during the final rinse.

3.The temperature of the incoming hot water must maintain a minimum temperature of 140°F/60°C for a 40°F/22°C rise booster or a minimum temperature of 110°F/43°C for a 70°F/39°C rise booster.

4.A manually operated 3/4" or larger shut-off valve should be installed in the incoming line as close to the dishwasher as possible for servicing.

Drain Connection

The drain water connection is a 2" slip-fit hose connection and is located at the center-rear of the machine base. It is a gravity drain.

1.The dishwasher drain is 2" O.D. hose connection.

2.A optional drain water tempering kit is available (consult the factory).

3.Drain water flow is controlled by an automatic electrically operated drain valve.

4.The floor sink and/or drain plumbing must be able to accommodate a maximum drain flow rate of

20 US gpm / 17 Imp gpm / 76 Lpm.

The incoming hot water line is a 3/4" NPT connection.

The drain is a 2" slip-fit hose connection.

NOTE:

Plumbing connections must comply with all national and/or local plumbing and sanitary codes.

6