Installation
Electrical Connections
Field Conversion from 3-phase to 1-phase Operation
A standard
A jumper wire, jumper bars and a new data plate are stowed on top of the wash tank heater junction box.
To convert the dishwasher from
Install Main Terminal Block Jumper Wire
1.Disconnect all power to the machine.
2.Remove the
3.Connect the jumper wire (shipped inside the control cabinet) between L2 and L3 on the output side of the main terminal block.
4.Connect the
Rewire Wash Tank Heater Element for 1PH
1.Remove the lower front panel.
2.Remove the wash tank heater junction box cover.
3.Remove the paper insulator and jumper bars from the heater terminals.
4.Additional short jumper bars are stowed with the new data plate.
5.Reposition the jumper bars for 1PH as shown below.
6.Connect the #33 wire to one element terminal as shown.
7.Connect the #34 and #35 wires to the other terminals as shown.
8.Reinstall the paper insulator and the junction box cover.
SINGLE PHASE
POWER CONNECTION
LINE IN
GRD L1 L2
L1 | L2 | L3 |
JUMPER
Connect the jumper wire between L2 and L3 on the output side of the main terminal block
| L1 |
|
|
| 33 |
| L1 |
| L2 |
| |
| 34 |
| 33 |
3PH | L3 |
| L2 |
35 |
| ||
| 1PH | L3 | 34 |
|
| 35 |
|
Rewire Booster Heater Element for 1PH
1.Remove the booster heater element cover.
2.Remove the paper insulator and jumper bars from the heater terminals.
3.Install the jumper bars for 1PH as shown below.
4.Additional short jumper bars are stowed with the new data plate.
5.Connect the #36 wire to one element terminal as shown.
6.Connect the #37 and #38 wires to the other terminals as shown.
7.Reinstall the paper insulator and the booster heater element cover.
3PH | L3 | 1PH |
| 38 |
|
37 | 36 | 38 |
| 36 |
L2 | L1 |
| ||
|
|
| ||
|
| L3 | 37 | L1 |
|
|
| L2 |
|
NOTE: The additional jumper bars needed for 1PH operation are stowed with the new data plate on top of the wash tank heater junction box.
ATTENTION:
Affix the new data plate on top of the existing machine data plate to complete the conversion.