Read these instructions completely and carefully.

Quality of Flames

The combustion quality of burner flames needs to be determined visually.

(A) Yellow flames—

Call for service

(B) Yellow tips on outer cones— Normal for LP gas

(C) Soft blue flames—Normal for natural gas

If burner flames look like (A), call for service. Normal burner flames should look like (B) or (C), depending on the type of gas you use.

With LP gas, some yellow tipping on outer cones is normal.

Safety Instructions Operating Instructions Installation

Level the Range

Install the oven shelves in the oven and position the range where it will be installed.

 

Raise

Lower

Lower

range

range

range

 

 

Leg leveler

Raise range

(on some models)

(on some models)

Check for levelness by placing a spirit level or a cup, partially filled with water, on one of the oven shelves. If using a spirit level, take two readings—with the level placed diagonally first in one direction and then the other.

Remove the warming drawer. See the Care and cleaning of the range section. The front leveling legs can be adjusted from the bottom and the rear legs can be adjusted from the top or the bottom.

Use an open-end or adjustable wrench to adjust the leveling legs until the range is level.

After the range is level, slide the range away from the wall so that the Anti-Tip device can be installed.

Instructions Troubleshooting Tips Consumer Support

51

Page 51
Image 51
GE J2B918 Safety Instructions Operating Instructions Installation, Quality of Flames, Level the Range, Yellow flames