E CONVERTING SURFACE BURNERS ON MODELS EQUIPPED WITH SEALED BURNERS
(See Step 4 if range is equipped with standard twin burners.)
1.Remove grates, burner caps and burner heads.
2.Using a torxdriver, remove the burner bases by unscrewing the 3 small screws in each base. Lift the burner straight out.
DO NOT disconnect the wires from the burner bases unless the cooktop needs to be raised.
3.Remove the brass orifice spud under each burner base by unscrewing spud from fitting with a 7 mm or a small adjustable wrench (depending on the size of your spuds). Apply a 3/4” wrench to the hex on the gas inlet tube as a
4.Install or~lce spuds according to one of the
following diagrams (sqe ❑ or ~), for LP gas or natural gas, depending on which you are
converting to.
❑orifice Spuds forconvetiingto LpG~s:
LP otilce spuds are in a small plastic bag packed with this Use and Care Guide. LP otilce spuds have a
❑OrifiCeSpudsfor ConVetiingto Natu~al Gas:
Natural gas orifice spuds have a
(continued next page)
45