HOW TO CONVERT THE RANGE FOR USE

WITH 1P GAS OR NATURAL GAS (continued)

CONVERT TOP BURNER VALVES

1. Turn all of the top burners to LOW.

2. Remove all four knobs.

\

3.With a small flat blade screwdriver, turn the

valve set screws <+a~ clockwise to decrease the

flame size. counterclockwise \. . I to increase the flame size. Adjust

until the flame is about the same \ 5/ height as the top of the burner.

4. Replace the knobs.

Y

5.Check for flame outage by opening and closing the oven door several times. If the flame goes out, increase the flame size.

CHECK QUALITY OF FMES

The combustion quality of burner flames needs to be determined visually.

(A) Yellow flames—

Call for service

(B) Yellow tips on outer cones— Normal for LP gas

(C) ~fi blue flamee Normal for natural gas

If burner flames look like (A), call for service. Normal burner flames should look like (B) or (C), depending on the type of gas you use.

With LP gas, some yellow tipping on outer cones is normal.