E CONVERT THE OVEN BURNER ORIFICES

E CONVERT THE OVEN BURNER ORIFICES

Oven Burner

1. Remove oven door, storage drawer or broiler

drawer, oven bottom and burner baffle (on some

CONVERT AIR ADJUSTMENT SHUTTER

For U gas, loosen the Phillips head screw and rotate the shutter to the

Screwfull open position. With

models). The lower burner orifice spud is

located behind the storage drawer, broiler

drawer or kick panel. (On some models, a metal

shield must be removed to access the ortilce.)

Air Shutter

baffle in place, flames should have approximately l-inch blue cones and should not extend beyond

2. To convert to U gas,

use a 1/2” wrench to turn the lower burner ortice spud clockwise. Tighten the spud only until it is snug. To prevent damage, do not overtighten the spud.

To convert to natiral gas, loosen the spud about 2 turns.

Broil Burner (on some models)

To convert to U gas, use a 1/2” wrench to turn the upper burner orifice spud clockwise. Tighten spud only until it is snug with the base. To prevent damage, do not overtighten spud.

To convert to natird gas, loosen the spud

about 2 turns.

the edges of the burner baffle. After 30 seconds of burner operation, check for flames lifting off burner ports. U lifting is observed, gradually reduce air shutter opening until flames are stabilized.

For natiral gas, the shutter should be open 1/2” or about 3/4 of the way open.

CHECK FOR LEAKS

When all connections have been made, make sure all range controls are in the off position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system.

CA~ON: DO NOT USE A FME TO CHECK FOR GAS ~.

When using test pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual shut-off valve from the gas supply piping. When using test pressures of 1/2 psig or less to test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve.

(continued next page)