EXHAUST BLOWER RATINGS

Installation Instructions

EXHAUST BLOWER RATINGS

EXHAUST BLOWER SAFETY WARNING

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of other fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities.

NOTE: The exhaust blower output is approximately 400 CFM (cubic feet per minute) without ductwork. Each installation is different and ductwork affects blower output accordingly. Actual blower exhaust CFM can be approximated using the graph below.

Step 1: Calculate the “equivalent duct length” using the “DUCTWORK

CALCULATIONS” table in these instructions for your installation.

Step 2: Find the approximate intersection point of the blower exhaust performance curve with the equivalent duct length to estimate the actual maximum blower output for your installation.

Examples: 50 equivalent feet of ductwork has approximately 320 CFM. 100 equivalent feet of ductwork has approximately 265 CFM.

Downdraft Cooktop Exhaust Blower CFM

 

450

 

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

350

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

Flow (CFM)

250

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

Air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

0

0

25

50

75

100

125

150

6” Diameter Equivalent Duct Length