Installation Instructions
POWER SUPPLY LOCATIONS
GAS SUPPLY:
These cooktops are designed to operate on natural gas at 4″ of water column pressure or on LP gas at 10″ of water column pressure.
ELECTRICAL SUPPLY:
• These cooktops are shipped from the |
factory set for natural gas. If you decide to |
use this cooktop with LP gas, conversion |
adjustments must be made by a service |
technician or other qualified person. |
• The pressure regulator must be connected in |
series with the manifold of the cooktop and |
must remain in series with the supply line |
regardless of type of gas being used. |
For proper operation, the maximum inlet |
291⁄2″
Gas pipe location
2″ | Electrical | |
Min | ||
3″ | outlet 12″ | |
above | ||
Min | ||
C | cabinet floor | |
L | (mount on | |
| side or back | |
| cabinet wall | |
| 2″ min. from | |
| centerline) |
pressure to the regulator must be no more |
than 10″ water column pressure for natural |
gas and 14″ water column pressure for LP |
gas. |
• When checking the regulator, the inlet |
pressure must be at least 1″ greater than the |
regulator output setting. If the regulator is |
set for 4″ of water column pressure, the inlet |
pressure must be at least 5″. If the regulator |
is set for 10″ of water column pressure, the |
inlet pressure must be at least 11″. For ease |
of installation, and if local codes permit, the |
gas supply line into the cooktop should be |
1/2″ or 3/4″ ID flexible metal appliance |
connector, three to five feet long. |
NOTE: Purchase a new flexible line. DO NOT |
USE AN OLD PREVIOUSLY USED LINE. |
• Make gas connection through rear wall, or |
on cabinet floor at rear, as illustrated. |
4″ (to clear toe kick area)
The
or circuit breaker, is required.
•A properly grounded
IMPORTANT: (Please read carefully.) FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
The power cord of this appliance is equipped with a
a qualified electrician to make sure the receptacle is properly grounded and has correct polarity.
Where a standard
Do Not, Under Any Circumstances, Cut Or Remove The Third (ground) Prong From The Power Cord.
Do not use an extension cord.
23