Installation Instructions
AWhen making the wire connections, use the entire length of conduit provided. The conduit must not be shortened.
BWith the cooktop in place, open the front of the cabinet door.
CInsert the wires from the conduit through the opening of the junction box.
EOnce the connections are made, secure wires together using wire nuts.
Red
Strain Relief Clamp
Ground
Black
Red | Strain Relief Clamp |
Ground
Black
DConnect the red and black leads from the cooktop conduit to the corresponding leads in the junction box.
Red
Ground wire | Black |
location |
|
GROUNDING INSTRUCTIONS:
The bare ground wire in the conduit is connected to the cooktop frame. Effective January 1, 1996, the National Electrical Code will not permit grounding through neutral. If used in new construction after January 1, 1996 or in a mobile home, recreational vehicle or if local codes do not permit grounding through the neutral white lead, attach the appliance grounding lead (green or copper) to the residence grounding conductor (green or bare copper) in accordance with local codes. When connecting to a 3 conductor branch circuit, if local codes permit, connect the bare ground connector lead of the cooktop to the branch circuit neutral (gray or white in color).
IMPORTANT: If the cooktop is being installed into a blind counter (one with no cabinet opening below), wire connections must be made before putting the cooktop into the cutout opening.