GE Series 90-70 manual Chapter Programming Guide, Overview

Models: Series 90-70

1 42
Download 42 pages 32.41 Kb
Page 27
Image 27

Chapter

4

Programming Guide

This chapter explains how to incorporate logic for one to four I/O Link Interface Modules in an application program for the Series 90±70 PLC. Programming instructions for other devices on the link are not included.

Overview

The Program Blocks on the diskettes provided with the I/O Link Interface Module will transfer input and output data between the Series 90±70 PLC and up to four I/O Link Interface Modules. The Program Blocks also monitor diagnostics from each I/O Link Interface Module in the PLC, and provide a mechanism for controlling link operation from the application program.

One Program Block is selected for the application, and added to the application program using the Librarian function of Logicmaster 90±70.

Logic must be added to the application program to call the Program Block, which will execute once each time it is called. Normally, it is called once per PLC sweep.

The Program Block utilizes a range of %P references, set aside in PLC memory, to exchange data with the Series 90±70 PLC. The application program interfaces with the Program Block by reading and writing the same %P references. The Program Block also makes use of a small group of %G references. These do not require any application program interaction. However, it is important to be sure that these %G references are not used for any other purpose.